  • Views:

(Summary description)The original busway was mounted in a non-ventilated steel casing by a bare copper conductor supported on an inorganic insulator such as a porcelain insulator. At that time, this type of structure was suitable for rated currents of 225 to 600A. Due to the expanded application range of the busway, the increased load requires a larger rated current value, and when the capacity is larger, the busway housing is additionally ventilated for better cooling conditions. For safety, the busbar package is insulated and the busbars of opposite polarity can be brought closer together to achieve lower reactance and voltage drop.

Intensive busway has four types of busway with all accessories and accessories

(Summary description)The original busway was mounted in a non-ventilated steel casing by a bare copper conductor supported on an inorganic insulator such as a porcelain insulator. At that time, this type of structure was suitable for rated currents of 225 to 600A. Due to the expanded application range of the busway, the increased load requires a larger rated current value, and when the capacity is larger, the busway housing is additionally ventilated for better cooling conditions. For safety, the busbar package is insulated and the busbars of opposite polarity can be brought closer together to achieve lower reactance and voltage drop.

  • Categories:Zhongrui News
  • Author:
  • Origin:
  • Time of issue:2019-05-28 15:14
  • Views:
Information
The original busway was mounted in a non-ventilated steel casing by a bare copper conductor supported on an inorganic insulator such as a porcelain insulator. At that time, this type of structure was suitable for rated currents of 225 to 600A. Due to the expanded application range of the busway, the increased load requires a larger rated current value, and when the capacity is larger, the busway housing is additionally ventilated for better cooling conditions. For safety, the busbar package is insulated and the busbars of opposite polarity can be brought closer together to achieve lower reactance and voltage drop.
 
In the late 1950s, heat transfer conduction techniques were extended to busbars by providing heat transfer contact between the insulated conductor and the outer casing. Due to the application of heat transfer technology, the fully enclosed busway has the same current density as the above-mentioned ventilation bus. This type of fully enclosed busway is rated for the same current regardless of where it is installed. Each phase uses a busbar of a busbar with a busbar width of 150mm (1.6kA). Higher rated currents require two sets (3kA) or three sets (5kA). Each set of busbars includes all three phases and neutrals to reduce line impedance.
 
In the earlier busway design, multiple nuts, bolts and washers were required for the connection of the conductive plates in the adjacent sections. In recent designs, each set of busbars is connected by only one bolt. The factory busbar section is shipped with all accessories. Installation work is greatly reduced and installation costs are saved. The busway can be made of a copper conductor or an aluminum conductor. Compared with copper, aluminum has a lower electrical conductivity and a lower mechanical strength. When exposed to air, its surface quickly forms an insulating film. When the current carrying capacity is the same, the weight of aluminum is lighter and the cost is less. For these reasons, the aluminum conductor should have an electroplated contact surface (tin or silver) and a disc spring and bolt connection at the electrical connection point to accommodate the mechanical properties of the aluminum.
 
Copper plug-in busbars are more adaptable to periodic loads like welding machines. The busway is usually made into a section of 30 cm. Because the busway must be compatible with the building, there are various combinations of bends, T-connections, cross-connections, and the like. There are feed and tap devices that lead to other electrical equipment such as switch boards, transformers, motor control centers, and the like. The plug for the plug-in busway uses a fuse switch and a die-shell circuit breaker. For single-phase and three-phase busway, the standard rated current is 20~5000A.
 
The dense busway has four types of busway, together with all accessories and accessories, to form a unified, fully enclosed busbar system: feeder busway for low-impedance transmission; easy to connect or easy to re-arrange the load Busway; a lighting busway that supports fluorescent lamps, high-intensity discharge lamps, incandescent lamps, and power supply; it is a sliding-type busway for "tapping" mobile power supplies such as electric hoists, cranes, and hand tools.

Scan the QR code to read on your phone

ABOUT US

 

 

Introduction

 

Business

 

Win-win

 

Advantage

 

Contact us

NEWS

 

 

Zhongrui News

 

Industry

 

FAQ

 

Support

 

CONTACT US

Add:92 Weier Road, Chengbei Park, Jingjiang Economic and Technological Development Zone, Jiangsu Province 

Phone

Mobile version